80W ~ 130W Max.
Features:
• 100 --240VAC Universal Input
• Active PFC Function
• LED Indicator
• Protections:
• Short Circuit / Over Voltage / Over Current Over Temperature
• Energy Efficiency Level VI or CoC Tier II
• No Load Power Consumption:
CEC level VI: ≤0.21W
CoC Tier II: ≤0.15W
• MTBF > 100,000 hours
HA1120 X Y
X: AC Inlet: 1.C14 2.C8 3.C6
Y: Output voltage range
MODEL No. | MAX. OUTPUT POWER (W) | OUTPUT VOLTAGE (Vo) | MIN. | MAX. | LOAD REGULATION | LINE REGULATION | RIPPLE & NOISE |
LOAD(Io) | LOAD(Io) | ||||||
HA1120XA | 80W | 12-16V | 0A | 6.66A | ± 5% | ± 1% | 240mV |
HA1120XB | 90W | 12-16V | 0A | 7.5A | ± 5% | ± 1% | 240mV |
HA1120XC | 90W | 19-24V | 0A | 4.73A | ± 5% | ± 1% | 360mV |
HA1120XD | 100W | 12-16V | 0A | 8.33A | ± 5% | ± 1% | 240mV |
HA1120XE | 100W | 19-24V | 0A | 5.26A | ± 5% | ± 1% | 360mV |
HA1120XF | 110W | 12-16V | 0A | 9.16A | ± 5% | ± 1% | 240mV |
HA1120XG | 110W | 19-24V | 0A | 5.78A | ± 5% | ± 1% | 360mV |
HA1120XH | 120W | 12-16V | 0A | 10A | ± 5% | ± 1% | 240mV |
HA1120XJ | 120W | 19-24V | 0A | 6.31A | ± 5% | ± 1% | 360mV |
HA1120XK | 100W | 48-56V | 0A | 2.08A | ± 5% | ± 1% | 840mV |
HA1120XL | 130W | 48-56V | 0A | 2.70A | ± 5% | ± 1% | 840mV |
HA1120XL | 120W | 36V | 0A | 3.33A | ± 5% | ± 1% | 840mV |
NOTE: 1: Ripple & Noise is measured by using 20MHz bandwidth limited oscilloscope and terminated each output with a 0.1uF ceramic capacitor & parallel with 47uF aluminum capacitor at full load and nominal line. 2: Line regulation is defined by changing ±10% of input voltage from nominal line at rated load. 3: Max. Power (W) >=Vo x Io Electrical Specification INPUT • Input Range 100 to 240VAC • Frequency 50 to 60Hz • Input Current <= 2.0A • Inrush Current 60A/100VAC 120A/230VAC • Hold Up Time ≥8.3ms • Turn On Time <=3s OUTPUT •Over Voltage Protection Latch off •Short Circuit Protection Auto Recovery/Latch off •Over Current Protection Auto Recovery/Latch off •Over Temperature Protection Latch off ENVIRONMENTAL •Operating Temperature 0 to 40°C •Storage Temperature -20 to 85°C •Operation Humidity 10% to 90 % •Storage Humidity 5% to 95 % • Certified for the whole series: EN 62368-1,CCC Mechanical Specification Product Introduction
Product Advantage
Product UsesThere are a variety of ways that people can use plug adapters. One of the most popular ways is to use it as a way to convert AC power into DC power. This can be useful for people who have devices that only work with DC power, such as laptops or digital cameras. Another common use for plug adapters is to use them as a way to charge batteries. This can be helpful for people who need to charge multiple batteries at once, or for people who need to charge batteries in difficult-to-reach places. |
80W ~ 130W Max.
Features:
• 100 --240VAC Universal Input
• Active PFC Function
• LED Indicator
• Protections:
• Short Circuit / Over Voltage / Over Current Over Temperature
• Energy Efficiency Level VI or CoC Tier II
• No Load Power Consumption:
CEC level VI: ≤0.21W
CoC Tier II: ≤0.15W
• MTBF > 100,000 hours
HA1120 X Y
X: AC Inlet: 1.C14 2.C8 3.C6
Y: Output voltage range
MODEL No. | MAX. OUTPUT POWER (W) | OUTPUT VOLTAGE (Vo) | MIN. | MAX. | LOAD REGULATION | LINE REGULATION | RIPPLE & NOISE |
LOAD(Io) | LOAD(Io) | ||||||
HA1120XA | 80W | 12-16V | 0A | 6.66A | ± 5% | ± 1% | 240mV |
HA1120XB | 90W | 12-16V | 0A | 7.5A | ± 5% | ± 1% | 240mV |
HA1120XC | 90W | 19-24V | 0A | 4.73A | ± 5% | ± 1% | 360mV |
HA1120XD | 100W | 12-16V | 0A | 8.33A | ± 5% | ± 1% | 240mV |
HA1120XE | 100W | 19-24V | 0A | 5.26A | ± 5% | ± 1% | 360mV |
HA1120XF | 110W | 12-16V | 0A | 9.16A | ± 5% | ± 1% | 240mV |
HA1120XG | 110W | 19-24V | 0A | 5.78A | ± 5% | ± 1% | 360mV |
HA1120XH | 120W | 12-16V | 0A | 10A | ± 5% | ± 1% | 240mV |
HA1120XJ | 120W | 19-24V | 0A | 6.31A | ± 5% | ± 1% | 360mV |
HA1120XK | 100W | 48-56V | 0A | 2.08A | ± 5% | ± 1% | 840mV |
HA1120XL | 130W | 48-56V | 0A | 2.70A | ± 5% | ± 1% | 840mV |
HA1120XL | 120W | 36V | 0A | 3.33A | ± 5% | ± 1% | 840mV |
NOTE: 1: Ripple & Noise is measured by using 20MHz bandwidth limited oscilloscope and terminated each output with a 0.1uF ceramic capacitor & parallel with 47uF aluminum capacitor at full load and nominal line. 2: Line regulation is defined by changing ±10% of input voltage from nominal line at rated load. 3: Max. Power (W) >=Vo x Io Electrical Specification INPUT • Input Range 100 to 240VAC • Frequency 50 to 60Hz • Input Current <= 2.0A • Inrush Current 60A/100VAC 120A/230VAC • Hold Up Time ≥8.3ms • Turn On Time <=3s OUTPUT •Over Voltage Protection Latch off •Short Circuit Protection Auto Recovery/Latch off •Over Current Protection Auto Recovery/Latch off •Over Temperature Protection Latch off ENVIRONMENTAL •Operating Temperature 0 to 40°C •Storage Temperature -20 to 85°C •Operation Humidity 10% to 90 % •Storage Humidity 5% to 95 % • Certified for the whole series: EN 62368-1,CCC Mechanical Specification Product Introduction
Product Advantage
Product UsesThere are a variety of ways that people can use plug adapters. One of the most popular ways is to use it as a way to convert AC power into DC power. This can be useful for people who have devices that only work with DC power, such as laptops or digital cameras. Another common use for plug adapters is to use them as a way to charge batteries. This can be helpful for people who need to charge multiple batteries at once, or for people who need to charge batteries in difficult-to-reach places. |
HIENT Power Technology Co., Ltd. is the technology enterprises engaged in the development, design, manufacture and sale of power supply and power system.Power supply product includes adapter, charger, industry power... Read More